Github user kl0u commented on the issue:

    https://github.com/apache/flink/pull/1813
  
    Hi @subhankarb ! By playing around with the sink during testing, I saw that if Redis goes
down in the middle of the execution of  a job, the job has to wait until the next element
(after the Redis failure) arrives in order to detect that it is down.
    
    This is not the expected behavior, as we want the job to fail as soon as Redis goes down.
Do you have an idea of why this is happening or how to fix it?


---
If your project is set up for it, you can reply to this email and have your
reply appear on GitHub as well. If your project does not have this feature
enabled and wishes so, or if the feature is enabled but not working, please
contact infrastructure at infrastructure@apache.org or file a JIRA ticket
with INFRA.
---