flink-issues mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From joshfg <...@git.apache.org>
Subject [GitHub] flink issue #2269: [FLINK-4190] Generalise RollingSink to work with arbitrar...
Date Mon, 25 Jul 2016 11:48:49 GMT
Github user joshfg commented on the issue:

    https://github.com/apache/flink/pull/2269
  
    Ah I see, that makes sense.
    I've began refactoring the tests here: https://github.com/joshfg/flink/blob/flink-4190/flink-streaming-connectors/flink-connector-filesystem/src/test/java/org/apache/flink/streaming/connectors/fs/bucketing/BucketingSinkTest.java
    
    But have run into this strange exception in the `testNonRollingSequenceFileWithoutCompressionWriter`
test:
    ```
    java.lang.IllegalStateException: Key Class has not been initialized.
    	at org.apache.flink.streaming.connectors.fs.SequenceFileWriter.open(SequenceFileWriter.java:84)
    	at org.apache.flink.streaming.connectors.fs.bucketing.BucketingSink.openNewPartFile(BucketingSink.java:500)
    	at org.apache.flink.streaming.connectors.fs.bucketing.BucketingSink.invoke(BucketingSink.java:396)
    	at org.apache.flink.streaming.api.operators.StreamSink.processElement(StreamSink.java:39)
    	at org.apache.flink.streaming.util.OneInputStreamOperatorTestHarness.processElement(OneInputStreamOperatorTestHarness.java:226)
    	at org.apache.flink.streaming.connectors.fs.bucketing.BucketingSinkTest.testNonRollingSequenceFileWithoutCompressionWriter(BucketingSinkTest.java:220)
    ```
    
    Any ideas what would cause that? I've copied the HDFS cluster initialisation exactly as
it was in the original tests...
    
    



---
If your project is set up for it, you can reply to this email and have your
reply appear on GitHub as well. If your project does not have this feature
enabled and wishes so, or if the feature is enabled but not working, please
contact infrastructure at infrastructure@apache.org or file a JIRA ticket
with INFRA.
---