Ufuk Celebi created FLINK-5040:
----------------------------------

             Summary: Set correct input channel types with eager scheduling
                 Key: FLINK-5040
                 URL: https://issues.apache.org/jira/browse/FLINK-5040
             Project: Flink
          Issue Type: Bug
          Components: JobManager
            Reporter: Ufuk Celebi
            Assignee: Ufuk Celebi
             Fix For: 1.2.0, 1.1.4


When we do eager deployment all intermediate stream/partition locations are already known
when scheduling an intermediate stream/partition consumer. Nonetheless we saw tasks with "unknown
input channels" that were updated lazily during runtime. This was caused by a wrong producer
execution state check requiring the producers to be in RUNNING or DEPLOYING state when creating
consumer input channels.

(We had a bogus fix for this in FLINK-3232. With that "fix" we actually did not fix anything
correctly and instead doubled the number of schedule or update consumer messages we sent.)



--