[ https://issues.apache.org/jira/browse/FLINK-12351?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
ASF GitHub Bot updated FLINK-12351:
-----------------------------------
Labels: pull-request-available (was: )
> AsyncWaitOperator should deep copy StreamElement when object reuse is enabled
> -----------------------------------------------------------------------------
>
> Key: FLINK-12351
> URL: https://issues.apache.org/jira/browse/FLINK-12351
> Project: Flink
> Issue Type: Bug
> Components: API / DataStream
> Reporter: Jark Wu
> Priority: Major
> Labels: pull-request-available
> Fix For: 1.9.0
>
>
> Currently, AsyncWaitOperator directly put the input StreamElement into {{StreamElementQueue}}.
But when object reuse is enabled, the StreamElement is reused, which means the element in
{{StreamElementQueue}} will be modified. As a result, the output of AsyncWaitOperator might
be wrong.
> An easy way to fix this might be deep copy the input StreamElement when object reuse
is enabled, like this: https://github.com/apache/flink/blob/blink/flink-streaming-java/src/main/java/org/apache/flink/streaming/api/operators/async/AsyncWaitOperator.java#L209
--
This message was sent by Atlassian JIRA
(v7.6.3#76005)
|