metron-issues mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From "Nick Allen (JIRA)" <j...@apache.org>
Subject [jira] [Updated] (METRON-411) Support Greater Range of Profile Periods
Date Sat, 10 Sep 2016 12:19:20 GMT

     [ https://issues.apache.org/jira/browse/METRON-411?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]

Nick Allen updated METRON-411:
------------------------------
    Description: 
The current Profiler's deterministic row key design limits the range of valid profile period
durations.  The original goal was to support 15 minute periods which it does, along with 5,
20, 30 and 60 minute periods.  Different types of profiles and input data will require a range
of periods and the Profiler should be flexible in this regards.

Currently, a profile period must start on each and every hour.  While 1, 2, 3, 4, 6, or 240
periods per hour is acceptable, 5 periods per hour is not.  The number of periods per hour
must be either a multiple or divisor of 60.  Also, a period cannot be any longer than an hour.
 In some cases 2, 4, or 8 hour periods might be useful.

  was:
The current Profiler's deterministic row key design limits the range of valid profile period
durations.  The original goal was to support 15 minute periods which it does, along with 5,
20, 30 and 60 minute periods.  Different types of profiles and input data will require a range
of periods and the Profiler should be flexible in this regards.

Currently, a profile period must start on each and every hour.  While 1, 2, 3, 4, 6, or 240
periods per hour is acceptable, 5 periods per hour is not.  The number of periods per hour
must be either a multiple or divisor of 60.  Also, a period cannot be any longer than an hour.
 In some cases 2, 4, or 8 periods might be useful.


> Support Greater Range of Profile Periods 
> -----------------------------------------
>
>                 Key: METRON-411
>                 URL: https://issues.apache.org/jira/browse/METRON-411
>             Project: Metron
>          Issue Type: Improvement
>            Reporter: Nick Allen
>            Assignee: Nick Allen
>
> The current Profiler's deterministic row key design limits the range of valid profile
period durations.  The original goal was to support 15 minute periods which it does, along
with 5, 20, 30 and 60 minute periods.  Different types of profiles and input data will require
a range of periods and the Profiler should be flexible in this regards.
> Currently, a profile period must start on each and every hour.  While 1, 2, 3, 4, 6,
or 240 periods per hour is acceptable, 5 periods per hour is not.  The number of periods per
hour must be either a multiple or divisor of 60.  Also, a period cannot be any longer than
an hour.  In some cases 2, 4, or 8 hour periods might be useful.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Mime
View raw message