For the smallScanner feature, I implemented a CQD.



I defaulted it to ‘OFF’, but it can take ‘SYSTEM’ and ‘ON’.



When I do:

Control query default hbase_small_scanner ‘SYSTEM’;



And I check with:

Showcontrol defaults;



I get HBASE_SMALL_SCANNER OFF;





When I do:

Control query default hbase_small_scanner ‘ON’;



And I check with :

Showcontrol defaults;



I correctly get HBASE_SMALL_SCANNER ON;



Is there an obvious reason why this is happening or should I debug the code
to understand why?