Matthias J. Sax commented on FLINK-1985:
----------------------------------------

Hi again. I forgot to add, that I discoverd an unused member variable in ExecutionConfig,
namly disableAutoTypeRegistration. Should it be removed?

> Streaming does not correctly forward ExecutionConfig to runtime
> ---------------------------------------------------------------
>
>                 Key: FLINK-1985
>                 URL: https://issues.apache.org/jira/browse/FLINK-1985
>             Project: Flink
>          Issue Type: Bug
>          Components: Streaming
>    Affects Versions: 0.9
>            Reporter: Aljoscha Krettek
>            Assignee: Aljoscha Krettek
>            Priority: Blocker
>
> When running streaming jobs you see this log entry:
> "Environment did not contain an ExecutionConfig - using a default config."
> Some parts of the code use an ExecutionConfig at runtime. This will be a default config
without registered serializers and other user settings.



--