ignite-dev mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From Pavel Tupitsyn <ptupit...@apache.org>
Subject Re: Thin client protocol message format
Date Tue, 01 Aug 2017 17:03:52 GMT
Dmitry, we don't need any reserved bytes, because protocol is versioned.

On Tue, Aug 1, 2017 at 7:49 PM, <dsetrakyan@apache.org> wrote:

> We should also leave 8 bytes of empty space for future changes.
>
> ⁣D.​
>
> On Aug 1, 2017, 6:41 PM, at 6:41 PM, Pavel Tupitsyn <ptupitsyn@apache.org>
> wrote:
> >Alexey, good idea. ODBC and JDBC could also benefit from this.
> >
> >On Tue, Aug 1, 2017 at 7:27 PM, Alexey Kuznetsov
> ><akuznetsov@apache.org>
> >wrote:
> >
> >> Pavel,
> >>
> >> How about data compression?
> >> May be it make sense to add a byte with compression algorithm?
> >> 0 - none
> >> 1 - ZIP
> >> 2 - ....
> >> ....
> >>
> >> On Tue, Aug 1, 2017 at 11:10 PM, Pavel Tupitsyn
> ><ptupitsyn@apache.org>
> >> wrote:
> >>
> >> > Igniters,
> >> >
> >> > Below is a proposed design for thin client protocol [1] [2] socket
> >data
> >> > exchange format.
> >> >
> >> > * Values are little-endian
> >> > * Every request and response message starts with 4-byte length
> >(including
> >> > handshake)
> >> > * Ignite binary format is used for value serialization (via
> >> > GridBinaryMarshaller/BinaryWriter/BinaryReader). Ignite binary
> >protocol
> >> > has
> >> > to be implemented by clients anyway to work with cache values, so
> >it
> >> makes
> >> > sense to use for all data exchange.
> >> >
> >> >
> >> > 1) Socket connection is established on a port according
> >> > to ConnectorConfiguration.port
> >> >
> >> > 2) Handshake is performed.
> >> >  Request:
> >> >    int32 length = 8     // message length
> >> >    byte opCode = 1   // handshake command
> >> >    int16 verMajor
> >> >    int16 verMinor
> >> >    int16 verMaintenance
> >> >    byte clientCode = 2    // client type code (odbc, jdbc,
> >platform)
> >> >
> >> >  Response:
> >> >    uint32 length = 1
> >> >    byte success
> >> >
> >> > 3) Execute command. Request starts with a command code, then goes
> >> > command-specific data.
> >> > For example, IgniteCache<Integer, String>.put(1, "foo") will look
> >like
> >> > this:
> >> >  Request:
> >> >    int16 opCode    // OP_CACHE_GET
> >> >    int32 cacheId    // GridCacheUtils.cacheId
> >> >    byte flags          // skipStore, noRetry, etc
> >> >    binobject key
> >> >
> >> >  Response:
> >> >    byte success
> >> >    binobject value
> >> >
> >> > Where binobject corresponds to Ignite BinaryMarshaller format,
> >which is
> >> > produced by BinaryWriter.writeObject method. Integer will be
> >represented
> >> as
> >> >   byte typeCode = 3  // GridBinaryMarshaller.INT
> >> >   int32 value = 1
> >> >
> >> > 4) Goto (3)
> >> >
> >> >
> >> > Comments are welcome.
> >> >
> >> > Pavel
> >> >
> >> > [1]
> >> > http://apache-ignite-developers.2346864.n4.nabble.
> >> com/Support-for-Ignite-
> >> > clients-in-any-language-thin-client-protocol-td20297.html
> >> > [2] https://issues.apache.org/jira/browse/IGNITE-5896
> >> >
> >>
> >>
> >>
> >> --
> >> Alexey Kuznetsov
> >>
>

Mime