jmeter-dev mailing list archives

Site index · List index
Message view « Date » · « Thread »
Top « Date » · « Thread »
From Antonio Gomes Rodrigues <ra0...@gmail.com>
Subject Re: On nightly jmeter.bat not working in windows
Date Thu, 06 Sep 2018 09:11:47 GMT
If a use jmeterw.cmd without modification, it's doesn't works

jmeter.bat wotks fine

If I change "Apache JMeter" to "Apache_JMeter" in jmeterw.cmd, now
jmeterw.cmd works

Antonio

Le jeu. 6 sept. 2018 à 10:28, Felix Schumacher <
felix.schumacher@internetallee.de> a écrit :

> Am 06.09.2018 10:05, schrieb Antonio Gomes Rodrigues:
> > Hi,
> >
> > Tested with apache-jmeter-r1840164 in a windows 10 and it's works fine
> >
> > Can you give us more information (windows release...)
>
> I tested it here on windows 7 and it gave the same error message. It
> seems the cmd shell doesn't like a variable with spaces inside quotes.
> My workaround was to change "Apache JMeter" to "Apache_JMeter".
>
> Could both of you test if after those changes (in jmeter.cmd and
> jmeterw.cmd) the start script still work?
>
> Thanks,
>   Felix (who doesn't like windows batch scripts, especially their
> handling of spaces and quotes :)
>
> >
> > Le jeu. 6 sept. 2018 à 07:59, Jmeter Tea <jmetertea@gmail.com> a écrit
> > :
> >
> >>  Hello,
> >>
> >> jmeter.bat ot jmeterw stop working on nightly build, error in console
> >> :
> >> JMeter"" was unexpected at this time.
> >>
> >> I suspect the following change is relevant:
> >> if "%JM_START%" == "start" (
> >>     set JM_START=start "Apache JMeter"
> >> )
> >>
> >> FYI
> >>
>

Mime
  • Unnamed multipart/alternative (inline, None, 0 bytes)
View raw message